The five times sit‑to‑stand test: safety, validity and reliability with critical care survivors’s at ICU discharge

Authors

  • Thiago Araújo de Melo School of Health Sciences – Brazil, Universidade Federal do Rio de Janeiro, Rua das Patativas, 449, Imbui, Salvador, Bahia, Brazil
  • Fernando Silva Guimarães Physical Therapy Department, Federal University of Rio de Janeiro, Rua prof. Rodolpho Paulo Rocco, 255, oitavo andar, sala 3 ‑ Cidade Universitaria da Universidade Federal do Rio de Janeiro, Rio de Janeiro, RJ, Brazil
  • José Roberto Lapa e Silva School of Medicine – Federal University of Rio de Janeiro, Rua Ferreira Pontes, 264/103, Andarai, Rio de Janeiro, RJ, Brazil

DOI:

https://doi.org/10.1186/s40945-022-00156-z

Keywords:

ICU, Five Times Sit-to-Stand Test (FTSST), Physical therapy, Rehabilitation

Abstract

Background The Five Times Sit-to-Stand Test (FTSST) has been found reliable, safe and valid for measuring healthy adults’ lower limb muscle strength and for determining balance control, fall risk, and exercise capacity among older examinees. We believe that the FTSST has the potential to be a straightforward, low cost and valuable tool for identifying muscle disability and functional status following critical illness. The aim of our study was to establish the applicability, safety, and psychometric qualities of FTSST in patients at Intensive Care Unit (ICU) discharge. Methods In our study applicability was determined by assessing the percentage of patients who could perform the test at ICU discharge. Safety was assessed by examining data regarding any exacerbated haemodynamic and respiratory responses or adverse events associated with the test. For assessing FTSST reliability, intraclass correlation coefficients (ICCs), standard error of measurement (SEM) and Bland-Altman plot were used. For assessing concurrent validity handgrip strength, ICU length of stay, duration of invasive ventilation, Simplified Acute Physiology Score 3 (SAPS3) and age variables were used. For investigating predictive validity, correlations between the FTSST and measures of hospital length of stay and functional independence were evaluated. Results Only 30% of ICU survivors (n = 261 out of 817) were eligible to perform the FTSST and 7% of patients who performed the test (n = 10 out of 142) presented adverse events. Both inter (ICC 0.92 CI95% 0.89–0.94) and intra-rater (ICC 0.95 CI95% 0.93–0.96) reliability were excellent and higher scores were associated with lower muscle strength, longer hospital stay and greater functional impairment at hospital discharge in adult survivors of critical diseases. Conclusion Our results suggest that the FTSST may be applicable only to high-functioning critical care survivors. In this specifical population, FTSST is a safe, easy to perform, valid and reliable measure that can be applied to fall risk and functional recovery management.

Downloads

Download data is not yet available.

Downloads

Published

2022-12-18

How to Cite

Melo, T. A. de, Guimarães, F. S., & Silva, J. R. L. e. (2022). The five times sit‑to‑stand test: safety, validity and reliability with critical care survivors’s at ICU discharge. Archives of Physiotherapy, 13(1). https://doi.org/10.1186/s40945-022-00156-z

Issue

Section

Research Article

Metrics