An experimental in vivo procedure for the standardised assessment of sealants retention over time

Authors

  • GF Ferrazzano Department of Neuroscience, Reproductive and Oral Sciences, Section of Paediatric Dentistry, University of Naples, Federico II Naples
  • S Orlando Department of Neuroscience, Reproductive and Oral Sciences, Section of Paediatric Dentistry, University of Naples, Federico II Naples
  • T Cantile Bambino Ges Hospital, Division of Dentistry and OrthodonticsRome
  • G Sangianantoni Department of Neuroscience, Reproductive and Oral Sciences, Section of Paediatric Dentistry, University of Naples, Federico II Naples
  • B Alcidi Department of Neuroscience, Reproductive and Oral Sciences, Section of Paediatric Dentistry, University of Naples, Federico II Naples
  • M Coda Department of Neuroscience, Reproductive and Oral Sciences, Section of Paediatric Dentistry, University of Naples, Federico II Naples
  • S Caruso Department of Life, Health, and Environmental Sciences University of L'Aquila, L'Aquila
  • A Ingenito Department of Neuroscience, Reproductive and Oral Sciences, Section of Paediatric Dentistry, University of Naples, Federico II Naples

DOI:

https://doi.org/10.23804/ejpd.2016.3.1.176

Keywords:

Dental caries prevention, Pit and fissure sealants, Sealants retention

Abstract

AIM: The elaboration of an experimental system to obtain reproducible and comparable photographs of the occlusal surface to monitor sealants retention. METHODS: An intraoral camera connected to a computer was used to obtain photos of the occlusal surfaces. A specific software was utilized to perform measurements on archived pictures. An experimental two-part system, consisting of a dental arch support and a camera support, connected to each other through holes and pins, was made to obtain a standardised and reproducible placement of the camera in the mouth. In the first part, to test the degree of reliability of the procedure and the percentage of image distortion, 120 first molars were sealed and for each molar ten photographs were taken, using the intraoral camera connected with the dental arch support, the camera support and the dedicated software. In the second part, 165 first molars were sealed and photographed, as above described, immediately after sealing (T0), 6 months (T1) and 1 year later (T2). With the software, the sealed areas were measured. The comparison of the selected sealed areas between T0 and T1, T0 and T2, T1 and T2 determined the percentage of sealant loss.

Similar Articles

1 2 3 4 5 6 7 8 9 10 > >> 

You may also start an advanced similarity search for this article.